Once the caller's frame has returned, any bytes that arrive late on the UART are written by the interrupt handler uart_cb_handler() through the dangling pointer into stack memory that the thread has since reused. The bytes come from the device on the other end of the UART. An attacker with physical access who replaces or impersonates the fingerprint module can trigger this by delaying a reply past the timeout and then sending a packet. A slow or faulty genuine module can also trigger it by accident.
The result is a write of attacker-chosen bytes into a live thread stack. The write length comes from the header of the late packet. Commit 96968fac22b, which landed together with this fix, bounds it to a header plus CONFIG_R502A_DATA_PKT_SIZE bytes; affected releases do not have that bound. This can crash the device and may allow control-flow hijacking, depending on what occupies the reused stack region. The fix disables the RX interrupt, resets the RX semaphore and clears rx_buf.data on timeout, and the interrupt handler now refuses to write when no receive buffer is armed.
Analysis and contextual insights are available on OpenCVE Cloud.
No solution or workaround provided in the CVE record.
Additional remediation guidance may be available on OpenCVE Cloud.
Tracking
Sign in to view the affected projects.
No advisories yet.
Wed, 25 Nov 2026 22:00:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | The Grow R502-A fingerprint sensor driver (drivers/sensor/grow_r502a/grow_r502a.c) points drv_data->rx_buf.data at an rx_packet buffer on the caller's stack and enables the UART RX interrupt before waiting 1500 ms for a reply. When the wait timed out, transceive_packet() returned -ETIMEDOUT but left the RX interrupt enabled and rx_buf.data still pointing at the caller's buffer. Once the caller's frame has returned, any bytes that arrive late on the UART are written by the interrupt handler uart_cb_handler() through the dangling pointer into stack memory that the thread has since reused. The bytes come from the device on the other end of the UART. An attacker with physical access who replaces or impersonates the fingerprint module can trigger this by delaying a reply past the timeout and then sending a packet. A slow or faulty genuine module can also trigger it by accident. The result is a write of attacker-chosen bytes into a live thread stack. The write length comes from the header of the late packet. Commit 96968fac22b, which landed together with this fix, bounds it to a header plus CONFIG_R502A_DATA_PKT_SIZE bytes; affected releases do not have that bound. This can crash the device and may allow control-flow hijacking, depending on what occupies the reused stack region. The fix disables the RX interrupt, resets the RX semaphore and clears rx_buf.data on timeout, and the interrupt handler now refuses to write when no receive buffer is armed. | |
| Title | Stack use-after-return on RX timeout in Grow R502-A fingerprint sensor driver | |
| Weaknesses | CWE-562 | |
| References |
| |
| Metrics |
cvssV3_1
|
Subscriptions
No data.
Status: PUBLISHED
Assigner: zephyr
Published:
Updated: 2026-11-25T20:27:18.338Z
Reserved: 2026-09-29T20:25:31.234Z
Link: CVE-2026-102959
No data.
Status : Awaiting Analysis
Published: 2026-11-25T21:17:15.943
Modified: 2026-11-25T21:17:16.053
Link: CVE-2026-102959
No data.
OpenCVE Enrichment
No data.
-
CWE-562
Return of Stack Variable Address