Export limit exceeded: 93890 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.
Search
Search Results (93890 CVEs found)
| CVE | Vendors | Products | Updated | CVSS v3.1 |
|---|---|---|---|---|
| CVE-2019-10958 | 1 Geutebrueck | 22 G-cam Ebc-2110, G-cam Ebc-2110 Firmware, G-cam Ebc-2111 and 19 more | 2024-11-21 | 7.2 High |
| Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated attacker with access to network configuration to supply system commands to the server, leading to remote code execution as root. | ||||
| CVE-2019-10957 | 1 Geutebrueck | 22 G-cam Ebc-2110, G-cam Ebc-2110 Firmware, G-cam Ebc-2111 and 19 more | 2024-11-21 | 4.8 Medium |
| Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated attacker with access to event configuration to store malicious code on the server, which could later be triggered by a legitimate user resulting in code execution within the user’s browser. | ||||
| CVE-2019-10956 | 1 Geutebrueck | 22 G-cam Ebc-2110, G-cam Ebc-2110 Firmware, G-cam Ebc-2111 and 19 more | 2024-11-21 | 7.2 High |
| Geutebruck IP Cameras G-Code(EEC-2xxx), G-Cam(EBC-21xx/EFD-22xx/ETHC-22xx/EWPC-22xx): All versions 1.12.0.25 and prior may allow a remote authenticated user, using a specially crafted URL command, to execute commands as root. | ||||
| CVE-2019-10951 | 1 Deltaww | 1 Cncsoft Screeneditor | 2024-11-21 | 7.8 High |
| Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. | ||||
| CVE-2019-10947 | 1 Deltaww | 1 Cncsoft Screeneditor | 2024-11-21 | 7.8 High |
| Delta Industrial Automation CNCSoft, CNCSoft ScreenEditor Version 1.00.88 and prior. Multiple stack-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. This may occur because CNCSoft lacks user input validation before copying data from project files onto the stack. | ||||
| CVE-2019-10933 | 1 Siemens | 4 Spectrum Power 3, Spectrum Power 4, Spectrum Power 5 and 1 more | 2024-11-21 | N/A |
| A vulnerability has been identified in Spectrum Power 3 (Corporate User Interface) (All versions <= v3.11), Spectrum Power 4 (Corporate User Interface) (Version v4.75), Spectrum Power 5 (Corporate User Interface) (All versions < v5.50), Spectrum Power 7 (Corporate User Interface) (All versions <= v2.20). The web server could allow Cross-Site Scripting (XSS) attacks if unsuspecting users are tricked into accessing a malicious link. User interaction is required for a successful exploitation. The user does not need to be logged into the web interface in order for the exploitation to succeed.At the stage of publishing this security advisory no public exploitation is known. | ||||
| CVE-2019-10928 | 1 Siemens | 2 Scalance Sc-600, Scalance Sc-600 Firmware | 2024-11-21 | 6.6 Medium |
| A vulnerability has been identified in SCALANCE SC-600 (V2.0). An authenticated attacker with access to port 22/tcp as well as physical access to an affected device may trigger the device to allow execution of arbitrary commands. The security vulnerability could be exploited by an authenticated attacker with physical access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the confidentiality, integrity and availability of the affected device. | ||||
| CVE-2019-10927 | 1 Siemens | 10 Scalance Xb-200, Scalance Xb-200 Firmware, Scalance Xc-200 and 7 more | 2024-11-21 | 6.5 Medium |
| A vulnerability has been identified in SCALANCE SC-600 (V2.0), SCALANCE XB-200 (V4.1), SCALANCE XC-200 (V4.1), SCALANCE XF-200BA (V4.1), SCALANCE XP-200 (V4.1), SCALANCE XR-300WG (V4.1). An authenticated attacker with network access to to port 22/tcp of an affected device may cause a Denial-of-Service condition. The security vulnerability could be exploited by an authenticated attacker with network access to the affected device. No user interaction is required to exploit this vulnerability. The vulnerability impacts the availability of the affected device. | ||||
| CVE-2019-10920 | 1 Siemens | 2 Logo\!8 Bm, Logo\!8 Bm Firmware | 2024-11-21 | 7.5 High |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). Project data stored on the device, which is accessible via port 10005/tcp, can be decrypted due to a hardcoded encryption key. The security vulnerability could be exploited by an unauthenticated attacker with network access to port 10005/tcp. No user interaction is required to exploit this security vulnerability. The vulnerability impacts confidentiality of the device. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
| CVE-2019-10918 | 1 Siemens | 4 Simatic Pcs 7, Simatic Wincc, Simatic Wincc \(tia Portal\) and 1 more | 2024-11-21 | 8.8 High |
| A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An authenticatd attacker with network access to the DCOM interface could execute arbitrary commands with SYSTEM privileges. The vulnerability could be exploited by an attacker with network access to the affected system. Successful exploitation requires authentication with a low-privileged user account and no user interaction. An attacker could use the vulnerability to compromise confidentiality and integrity and availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
| CVE-2019-10917 | 1 Siemens | 4 Simatic Pcs 7, Simatic Wincc, Simatic Wincc \(tia Portal\) and 1 more | 2024-11-21 | 5.5 Medium |
| A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC (TIA Portal) V13 (All versions), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1 Upd 9), SIMATIC WinCC (TIA Portal) V15 (All versions < V15.1 Upd 3), SIMATIC WinCC Runtime Professional V13 (All versions), SIMATIC WinCC Runtime Professional V14 (All versions < V14.1 Upd 8), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Upd 3), SIMATIC WinCC V7.2 and earlier (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 19), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd 11), SIMATIC WinCC V7.5 (All versions < V7.5 Upd 3). An attacker with local access to the project file could cause a Denial-of-Service condition on the affected product while the project file is loaded. Successful exploitation requires access to the project file. An attacker could use the vulnerability to compromise availability of the affected system. At the time of advisory publication no public exploitation of this security vulnerability was known. | ||||
| CVE-2019-10914 | 1 Matrixssl | 1 Matrixssl | 2024-11-21 | N/A |
| pubRsaDecryptSignedElementExt in MatrixSSL 4.0.1 Open, as used in Inside Secure TLS Toolkit, has a stack-based buffer overflow during X.509 certificate verification because of missing validation in psRsaDecryptPubExt in crypto/pubkey/rsa_pub.c. | ||||
| CVE-2019-10913 | 1 Sensiolabs | 1 Symfony | 2024-11-21 | N/A |
| In Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, HTTP Methods provided as verbs or using the override header may be treated as trusted input, but they are not validated, possibly causing SQL injection or XSS. This is related to symfony/http-foundation. | ||||
| CVE-2019-10909 | 2 Drupal, Sensiolabs | 2 Drupal, Symfony | 2024-11-21 | 5.4 Medium |
| In Symfony before 2.7.51, 2.8.x before 2.8.50, 3.x before 3.4.26, 4.x before 4.1.12, and 4.2.x before 4.2.7, validation messages are not escaped, which can lead to XSS when user input is included. This is related to symfony/framework-bundle. | ||||
| CVE-2019-10905 | 1 Parsedown | 1 Parsedown | 2024-11-21 | N/A |
| Parsedown before 1.7.2, when safe mode is used and HTML markup is disabled, might allow attackers to execute arbitrary JavaScript code if a script (already running on the affected page) executes the contents of any element with a specific class. This occurs because spaces are permitted in code block infostrings, which interferes with the intended behavior of a single class name beginning with the language- substring. | ||||
| CVE-2019-10904 | 2 Debian, Roundup-tracker | 2 Debian Linux, Roundup | 2024-11-21 | N/A |
| Roundup 1.6 allows XSS via the URI because frontends/roundup.cgi and roundup/cgi/wsgi_handler.py mishandle 404 errors. | ||||
| CVE-2019-10896 | 5 Canonical, Debian, Fedoraproject and 2 more | 5 Ubuntu Linux, Debian Linux, Fedora and 2 more | 2024-11-21 | 7.5 High |
| In Wireshark 2.4.0 to 2.4.13, 2.6.0 to 2.6.7, and 3.0.0, the DOF dissector could crash. This was addressed in epan/dissectors/packet-dof.c by properly handling generated IID and OID bytes. | ||||
| CVE-2019-10893 | 1 Centos-webpanel | 1 Centos Web Panel | 2024-11-21 | N/A |
| CentOS-WebPanel.com (aka CWP) CentOS Web Panel 0.9.8.793 (Free/Open Source Version) and 0.9.8.753 (Pro) is vulnerable to Stored/Persistent XSS for Admin Email fields on the "CWP Settings > "Edit Settings" screen. By changing the email ID to any XSS Payload and clicking on Save Changes, the XSS Payload will execute. | ||||
| CVE-2019-10892 | 1 Dlink | 2 Dir-806, Dir-806 Firmware | 2024-11-21 | N/A |
| An issue was discovered in D-Link DIR-806 devices. There is a stack-based buffer overflow in function hnap_main at /htdocs/cgibin. The function will call sprintf without checking the length of strings in parameters given by HTTP header and can be controlled by users. And it finally leads to a stack-based buffer overflow via a special HTTP header. | ||||
| CVE-2019-10887 | 1 Salicru | 1 Slc-20-cube3\(5\) | 2024-11-21 | 6.1 Medium |
| A reflected HTML injection vulnerability on Salicru SLC-20-cube3(5) devices running firmware version cs121-SNMP v4.54.82.130611 allows remote attackers to inject arbitrary HTML elements via a /DataLog.csv?log= or /AlarmLog.csv?log= or /waitlog.cgi?name= or /chart.shtml?data= or /createlog.cgi?name= request. | ||||