Search Results (55762 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2024-9129 1 Zend 1 Zend Server 2026-04-15 N/A
In versions of Zend Server 8.5 and prior to version 9.2 a format string injection was discovered. Reported by Dylan Marino
CVE-2024-9150 2026-04-15 N/A
Report generation functionality in Wyn Enterprise allows for code inclusion, but not sufficiently limits what code might be included. An attacker is able use a low privileges account in order to abuse this functionality and execute malicious code, load DLL libraries and executing OS commands on a host system with applications high privileges. This issue has been fixed in version 8.0.00204.0
CVE-2025-1073 2026-04-15 7.5 High
Panasonic IR Control Hub (IR Blaster) versions 1.17 and earlier may allow an attacker with physical access to load unauthorized firmware onto the device.
CVE-2025-0714 1 Mobatek 1 Mobaxterm 2026-04-15 6.5 Medium
The vulnerability exists in the password storage of Mobateks MobaXterm in versions below 25.0. MobaXTerm uses an initialisation vector (IV) consisting only of zero bytes and a master key to encrypt each password individually. In the default configuration, on opening MobaXTerm, the user is prompted for their password. A derivative of the password is used as the master key. As both the master key and the IV are the same for each stored password, the AES CFB ciphertext depends only on the plaintext (the password). The static IV and master key make it easier to obtain sensitive information and to decrypt data when it is stored at rest.
CVE-2025-0681 2026-04-15 6.2 Medium
The Cloud MQTT service of the affected products supports wildcard topic subscription which could allow an attacker to obtain sensitive information from tapping the service communications.
CVE-2025-0591 1 Omron 1 Cx-programmer 2026-04-15 7.8 High
Out-of-bounds Read vulnerability (CWE-125) was found in CX-Programmer. Attackers may be able to read sensitive information or cause an application crash by abusing this vulnerability.
CVE-2025-32899 1 Kde 1 Kdeconnect 2026-04-15 4.3 Medium
In KDE Connect before 1.33.0 on Android, a packet can be crafted that causes two paired devices to unpair. Specifically, it is an invalid discovery packet sent over broadcast UDP.
CVE-2025-32366 1 Connman 1 Connman 2026-04-15 4.8 Medium
In ConnMan through 1.44, parse_rr in dnsproxy.c has a memcpy length that depends on an RR RDLENGTH value, i.e., *rdlen=ntohs(rr->rdlen) and memcpy(response+offset,*end,*rdlen) without a check for whether the sum of *end and *rdlen exceeds max. Consequently, *rdlen may be larger than the amount of remaining packet data in the current state of parsing. Values of stack memory locations may be sent over the network in a response.
CVE-2025-48862 1 Bosch 1 Ctrlx Os 2026-04-15 7.1 High
Ambiguous wording in the web interface of the ctrlX OS setup mechanism could lead the user to believe that the backup file is encrypted when a password is set. However, only the private key - if available in the backup - is encrypted, while the backup file itself remains unencrypted.
CVE-2025-8076 1 Supermicro 1 Mbd-x13sedw-f 2026-04-15 7.2 High
There is a vulnerability in the Supermicro BMC web function at Supermicro MBD-X13SEDW-F. After logging into the BMC Web server, an attacker can use a specially crafted payload to trigger the Stack buffer overflow vulnerability.
CVE-2025-31929 2026-04-15 4.2 Medium
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions), UL Resi High End 40A w/15118 Hw (8EM1312-4CF18-0FA3) (All versions), UL Resi High End 48A w/15118 Hw (8EM1312-5CF18-0FA3) (All versions), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions). Affected devices do not contain an Immutable Root of Trust in M0 Hardware. An attacker with physical access to the device could use this to execute arbitrary code.
CVE-2025-3197 2026-04-15 7.3 High
Versions of the package expand-object from 0.0.0 are vulnerable to Prototype Pollution in the expand() function in index.js. This function expands the given string into an object and allows a nested property to be set without checking the provided keys for sensitive properties like __proto__.
CVE-2025-8424 1 Netscaler 2 Adc, Gateway 2026-04-15 N/A
Improper access control on the NetScaler Management Interface in NetScaler ADC and NetScaler Gateway when an attacker can get access to the appliance NSIP, Cluster Management IP or local GSLB Site IP or SNIP with Management Access
CVE-2025-32014 2026-04-15 N/A
estree-util-value-to-estree converts a JavaScript value to an ESTree expression. When generating an ESTree from a value with a property named __proto__, valueToEstree would generate an object that specifies a prototype instead. This vulnerability is fixed in 3.3.3.
CVE-2025-34141 2026-04-15 N/A
A reflected cross-site scripting (XSS) vulnerability exists in ETQ Reliance CG (legacy) platform within the `SQLConverterServlet` component. This vulnerability requires user interaction, such as clicking a crafted link, and may result in execution of unauthorized scripts in the user's context. The affected servlet was unnecessarily exposed to authenticated users and has since been disabled in version SE.2025.1.
CVE-2025-31930 2026-04-15 8.8 High
A vulnerability has been identified in IEC 1Ph 7.4kW Child socket (8EM1310-2EH04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Child socket/ shutter (8EM1310-2EN04-0GA0) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m (8EM1310-2EJ04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent cable 7m incl. SIM (8EM1310-2EJ04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket (8EM1310-2EH04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket incl. SIM (8EM1310-2EH04-3GA2) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter (8EM1310-2EN04-3GA1) (All versions < V2.135), IEC 1Ph 7.4kW Parent socket/ shutter SIM (8EM1310-2EN04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Child cable 7m (8EM1310-3EJ04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket (8EM1310-3EH04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Child socket/ shutter (8EM1310-3EN04-0GA0) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m (8EM1310-3EJ04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent cable 7m incl. SIM (8EM1310-3EJ04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket (8EM1310-3EH04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket incl. SIM (8EM1310-3EH04-3GA2) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter (8EM1310-3EN04-3GA1) (All versions < V2.135), IEC 3Ph 22kW Parent socket/ shutter SIM (8EM1310-3EN04-3GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Child cable 7m (8EM1310-3FJ04-0GA2) (All versions < V2.135), IEC ERK 3Ph 22 kW Child socket (8EM1310-3FH04-0GA0) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket (8EM1310-3FH04-3GA1) (All versions < V2.135), IEC ERK 3Ph 22 kW Parent socket incl. SI (8EM1310-3FH04-3GA2) (All versions < V2.135), UL Commercial Cellular 48A NTEP (8EM1310-5HF14-1GA2) (All versions < V2.135), UL Commercial Child 40A w/ 15118 HW (8EM1310-4CF14-0GA0) (All versions < V2.135), UL Commercial Child 48A BA Compliant (8EM1315-5CG14-0GA0) (All versions < V2.135), UL Commercial Child 48A w/ 15118 HW (8EM1310-5CF14-0GA0) (All versions < V2.135), UL Commercial Parent 40A with Simcard (8EM1310-4CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A (USPS) (8EM1317-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A BA Compliant (8EM1315-5CG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A with Simcard BA (8EM1310-5CF14-1GA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1310-5CG14-1GA1) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1314-5CG14-2FA2) (All versions < V2.135), UL Commercial Parent 48A, 15118, 25ft (8EM1315-5HG14-1GA2) (All versions < V2.135), UL Commercial Parent 48A,15118 25ft Sim (8EM1310-5CG14-1GA2) (All versions < V2.135), VersiCharge Blue™ 80A AC Cellular (8EM1315-7BG16-1FH2) (All versions < V2.135). Affected devices contain Modbus service enabled by default. This could allow an attacker connected to the same network to remotely control the EV charger.
CVE-2025-4690 1 Angularjs 1 Angularjs 2026-04-15 4.3 Medium
A regular expression used by AngularJS'  linky https://docs.angularjs.org/api/ngSanitize/filter/linky  filter to detect URLs in input text is vulnerable to super-linear runtime due to backtracking. With a large carefully-crafted input, this can cause a Regular expression Denial of Service (ReDoS) https://owasp.org/www-community/attacks/Regular_expression_Denial_of_Service_-_ReDoS  attack on the application. This issue affects all versions of AngularJS. Note: The AngularJS project is End-of-Life and will not receive any updates to address this issue. For more information see here https://docs.angularjs.org/misc/version-support-status .
CVE-2025-8531 3 Mitsubishi, Mitsubishi Electric, Mitsubishielectric 3 Melsec-q Series, Melsec-q Series, Melsec-q Series 2026-04-15 6.8 Medium
Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric Corporation MELSEC-Q Series Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, Q26UDVCPU, Q04UDPVCPU, Q06UDPVCPU, Q13UDPVCPU, and Q26UDPVCPU with the first 5 digits of serial No. "24082" to "27081" allows a remote attacker to cause an integer underflow by sending specially crafted packets to the affected product to stop Ethernet communication and the execution of control programs on the product, when the user authentication function is enabled. The user authentication function is enabled by default only when settings are configured by GX Works2, which complies with the Cybersecurity Law of the People's Republic of China, and is normally disabled.
CVE-2025-44879 2026-04-15 7.5 High
WS-WN572HP3 V230525 was discovered to contain a buffer overflow in the component /www/cgi-bin/upload.cgi. This vulnerability allows attackers to cause a Denial of Service (DoS) via a crafted HTTP request.
CVE-2025-40911 2026-04-15 6.5 Medium
Net::CIDR::Set versions 0.10 through 0.13 for Perl does not properly handle leading zero characters in IP CIDR address strings, which could allow attackers to bypass access control that is based on IP addresses. Leading zeros are used to indicate octal numbers, which can confuse users who are intentionally using octal notation, as well as users who believe they are using decimal notation. Net::CIDR::Set used code from Net::CIDR::Lite, which had a similar vulnerability CVE-2021-47154.