| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| A Padding Oracle exists in OSCI-Transport 1.2 as used in OSCI Transport Library 1.6.1 (Java) and OSCI Transport Library 1.6 (.NET). Under an MITM condition within the OSCI infrastructure, an attacker needs to send crafted protocol messages to analyse the CBC mode padding in order to decrypt the transport encryption. |
| Python package pysaml2 version 4.4.0 and earlier reuses the initialization vector across encryptions in the IDP server, resulting in weak encryption of data. |
| An issue was discovered in certain Apple products. Pages before 6.1, Numbers before 4.1, and Keynote before 7.1 on macOS and Pages before 3.1, Numbers before 3.1, and Keynote before 3.1 on iOS are affected. The issue involves the "Export" component. It allows users to bypass iWork PDF password protection by leveraging use of 40-bit RC4. |
| HKDF in cryptography before 1.5.2 returns an empty byte-string if used with a length less than algorithm.digest_size. |
| In the "NQ Contacts Backup & Restore" application 1.1 for Android, RC4 encryption is used to secure the user password locally stored in shared preferences. Because there is a static RC4 key, an attacker can gain access to user credentials more easily by leveraging access to the preferences XML file. |
| Seagate Business NAS devices with firmware before 2015.00322 allow remote attackers to execute arbitrary code with root privileges by leveraging use of a static encryption key to create session tokens. |
| Citrix NetScaler Application Delivery Controller (ADC) and NetScaler Gateway 10.5 before build 67.13, 11.0 before build 71.22, 11.1 before build 56.19, and 12.0 before build 53.22 might allow remote attackers to decrypt TLS ciphertext data by leveraging a Bleichenbacher RSA padding oracle, aka a ROBOT attack. |
| Sympa before 6.2.62 relies on a cookie parameter for certain security objectives, but does not ensure that this parameter exists and has an unpredictable value. Specifically, the cookie parameter is both a salt for stored passwords and an XSS protection mechanism. |
| The DeskLock tool provided with FactoryTalk View SE uses a weak encryption algorithm that may allow a local, authenticated attacker to decipher user credentials, including the Windows user or Windows DeskLock passwords. If the compromised user has an administrative account, an attacker could gain full access to the user’s operating system and certain components of FactoryTalk View SE. |
| In specific scenarios, on Windows the operator credentials may be encrypted in a manner that is not completely machine-dependent.
|
| Ovarro TBox TWinSoft uses the custom hardcoded user “TWinSoft” with a hardcoded key. |
| Fresenius Kabi Vigilant Software Suite (Mastermed Dashboard) version 2.0.1.3 issues authentication tokens to authenticated users that are signed with a symmetric encryption key. An attacker in possession of the key can issue valid JWTs and impersonate arbitrary users. |
| The use of a broken or risky cryptographic algorithm in Philips Vue PACS versions 12.2.x.x and prior is an unnecessary risk that may result in the exposure of sensitive information. |
| The SSL/TLS configuration of Fresenius Kabi Agilia Link + version 3.0 has serious deficiencies that may allow an attacker to compromise SSL/TLS sessions in different ways. An attacker may be able to eavesdrop on transferred data, manipulate data allegedly secured by SSL/TLS, and impersonate an entity to gain access to sensitive information. |
| Fresenius Kabi Agilia Link + version 3.0 does not enforce transport layer encryption. Therefore, transmitted data may be sent in cleartext. Transport layer encryption is offered on Port TCP/443, but the affected service does not perform an automated redirect from the unencrypted service on Port TCP/80 to the encrypted service. |
| The affected product has a hardcoded private key available inside the project folder, which may allow an attacker to achieve Web Server login and perform further actions. |
| MMP: All versions prior to v1.0.3, PTP C-series: Device versions prior to v2.8.6.1, and PTMP C-series and A5x: Device versions prior to v2.5.4.1 uses the MD5 algorithm to hash the passwords before storing them but does not salt the hash. As a result, attackers may be able to crack the hashed passwords. |
| Inadequate encryption may allow the passwords for Emerson OpenEnterprise versions through 3.3.4 user accounts to be obtained. |
| Rockwell Automation ISaGRAF Runtime Versions 4.x and 5.x includes the functionality of setting a password that is required to execute privileged commands. The password value passed to ISaGRAF Runtime is the result of encryption performed with a fixed key value using the tiny encryption algorithm (TEA) on an entered or saved password. A remote, unauthenticated attacker could pass their own encrypted password to the ISaGRAF 5 Runtime, which may result in information disclosure on the device. |
| By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection. |