| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| In clearFilter() in utilities.php in Cacti before 1.2.3, no escaping occurs before printing out the value of the SNMP community string (SNMP Options) in the View poller cache, leading to XSS. |
| On D-Link DI-524 V2.06RU devices, multiple Stored and Reflected XSS vulnerabilities were found in the Web Configuration: /spap.htm, /smap.htm, and /cgi-bin/smap, as demonstrated by the cgi-bin/smap RC parameter. |
| In GraphicsMagick 1.4 snapshot-20190322 Q8, there is a heap-based buffer overflow in the function WriteXWDImage of coders/xwd.c, which allows remote attackers to cause a denial of service (application crash) or possibly have unspecified other impact via a crafted image file. |
| In GraphicsMagick 1.4 snapshot-20190322 Q8, there is a stack-based buffer overflow in the function SVGStartElement of coders/svg.c, which allows remote attackers to cause a denial of service (application crash) or possibly have unspecified other impact via a quoted font family value. |
| In Materialize through 1.0.0, XSS is possible via the Toast feature. |
| In Materialize through 1.0.0, XSS is possible via the Autocomplete feature. |
| In Materialize through 1.0.0, XSS is possible via the Tooltip feature. |
| The D-Link DCS series of Wi-Fi cameras contains a stack-based buffer overflow in alphapd, the camera's web server. The overflow allows a remotely authenticated attacker to execute arbitrary code by providing a long string in the WEPEncryption parameter when requesting wireless.htm. Vulnerable devices include DCS-5009L (1.08.11 and below), DCS-5010L (1.14.09 and below), DCS-5020L (1.15.12 and below), DCS-5025L (1.03.07 and below), DCS-5030L (1.04.10 and below), DCS-930L (2.16.01 and below), DCS-931L (1.14.11 and below), DCS-932L (2.17.01 and below), DCS-933L (1.14.11 and below), and DCS-934L (1.05.04 and below). |
| ABB CP651 HMI products revision BSP UN30 v1.76 and prior implement hidden administrative accounts that are used during the provisioning phase of the HMI interface. |
| In WebAccess/SCADA, Versions 8.3.5 and prior, multiple stack-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| In WebAccess/SCADA Versions 8.3.5 and prior, multiple heap-based buffer overflow vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. Note: A different vulnerability than CVE-2019-10991. |
| In WebAccess/SCADA Versions 8.3.5 and prior, multiple out-of-bounds write vulnerabilities are caused by a lack of proper validation of the length of user-supplied data. Exploitation of these vulnerabilities may allow remote code execution. |
| Delta Electronics CNCSoft ScreenEditor, Versions 1.00.89 and prior. Multiple heap-based buffer overflow vulnerabilities may be exploited by processing specially crafted project files, allowing an attacker to remotely execute arbitrary code. There is a lack of user input validation before copying data from project files onto the heap. |
| SICK MSC800 all versions prior to Version 4.0, the affected firmware versions contain a hard-coded customer account password. |
| In Mitsubishi Electric MELSEC-Q series Ethernet module QJ71E71-100 serial number 20121 and prior, an attacker could send crafted TCP packets against the FTP service, forcing the target devices to enter an error mode and cause a denial-of-service condition. |
| NREL EnergyPlus, Versions 8.6.0 and possibly prior versions, The application fails to prevent an exception handler from being overwritten with arbitrary code. |
| Mitsubishi Electric FR Configurator2, Version 1.16S and prior. This vulnerability can be triggered when an attacker provides the target with a rogue project file (.frc2). Once a user opens the rogue project, CPU exhaustion occurs, which causes the software to quit responding until the application is restarted. |
| In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a stack-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long file name from the LIST command to the FTP service, which may cause the service to overwrite buffers, leading to remote code execution and escalation of privileges. |
| In Emerson Ovation OCR400 Controller 3.3.1 and earlier, a heap-based buffer overflow vulnerability in the embedded third-party FTP server involves improper handling of a long command to the FTP service, which may cause memory corruption that halts the controller or leads to remote code execution and escalation of privileges. |
| In Advantech WebAccess HMI Designer Version 2.1.9.23 and prior, processing specially crafted MCR files lacking proper validation of user supplied data may cause the system to write outside the intended buffer area, allowing remote code execution. |