| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
|
InHand Networks InRouter 302, prior to version IR302 V3.5.56, and InRouter 615, prior to version InRouter6XX-S-V2.3.0.r5542, contain vulnerability CWE-760: Use of a One-way Hash with a Predictable Salt. They
send MQTT credentials in response to HTTP/HTTPS requests from the cloud platform. These credentials are encoded using a hardcoded string into an MD5 hash. This string could be easily calculated by an unauthorized user who spoofed sending an HTTP/HTTPS request to the devices. This could result in the affected devices being temporarily disconnected from the cloud platform and allow the user to receive MQTT commands with potentially sensitive information.
|
| The webserver in Delta DX-3021 versions prior to 1.24 is vulnerable to
command injection through the network diagnosis page. This vulnerability
could allow a remote unauthenticated user to add files, delete files,
and change file permissions.
|
| The APDFL.dll contains a stack-based buffer overflow vulnerability that
could be triggered while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current
process.
|
|
The APDFL.dll contains an out-of-bounds write past the fixed-length
heap-based buffer while parsing specially crafted PDF files. This could
allow an attacker to execute code in the context of the current process.
|
|
The APDFL.dll contains a memory corruption vulnerability while parsing
specially crafted PDF files. This could allow an attacker to execute
code in the context of the current process.
|
|
Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to an out-of-bounds write which may allow an attacker to execute arbitrary code.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not validate the length of RTLS report payloads during communication. This allows an attacker to send an exceedingly long payload, resulting in an out-of-bounds write to cause a denial-of-service condition or code execution.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the monitor services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 contains hard-coded passwords for select users in the application’s database. This could allow a remote attacker to login to the database with unrestricted access.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 is vulnerable to cross-site scripting in its backup services. An attacker could take advantage of this vulnerability to execute arbitrary commands.
|
| Sewio’s Real-Time Location System (RTLS) Studio version 2.0.0 up to and including version 2.6.2 does not properly validate the input module name to the backup services of the software. This could allow a remote attacker to access sensitive functions of the application and execute arbitrary system commands.
|
|
Snap One Wattbox WB-300-IP-3 versions WB10.9a17 and prior are vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code or crash the device remotely.
|
| All versions of Landis+Gyr E850 (ZMQ200) are vulnerable to CWE-784: Reliance on Cookies Without Validation and Integrity. The device's web application navigation depends on the value of the session cookie. The web application could become inaccessible for the user if an attacker changes the cookie values.
|
| All versions prior to Delta Electronic’s CNCSoft version 1.01.34 (running ScreenEditor versions 1.01.5 and prior) are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code.
|
| Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to a stack-based buffer overflow, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.
|
| Delta Electronics DOPSoft versions 4.00.16.22 and prior are vulnerable to an out-of-bounds write, which could allow an attacker to remotely execute arbitrary code when a malformed file is introduced to the software.
|
| Delta Electronics DIAScreen versions 1.2.1.23 and prior are vulnerable to out-of-bounds write, which may allow an attacker to remotely execute arbitrary code.
|
|
Echelon SmartServer 2.2 with i.LON Vision 2.2 stores cleartext credentials in a file, which could allow an attacker to obtain cleartext usernames and passwords of the SmartServer. If the attacker obtains the file, then the credentials could be used to control the web user interface and file transfer protocol (FTP) server.
|
|
Control By Web X-400 devices are vulnerable to a cross-site scripting attack, which could result in private and session information being transferred to the attacker.
|
| If an attacker were to access memory locations of LS ELECTRIC XBC-DN32U with operating system version 01.80 that are outside of the communication buffer, the device stops operating. This could allow an attacker to cause a denial-of-service condition.
|