| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| When the device is configured to perform account lockout with a defined period of time, any unauthenticated user attempting to log in as root with an incorrect password can trigger a lockout of the root account. When an SRX Series device is in cluster mode, and a cluster sync or failover operation occurs, then there will be errors associated with synch or failover while the root account is locked out. Administrators can confirm if the root account is locked out via the following command root@device> show system login lockout user root User Lockout start Lockout end root 1995-01-01 01:00:01 PDT 1995-11-01 01:31:01 PDT Affected releases are Juniper Networks Junos OS 12.1X46 prior to 12.1X46-D65 on SRX series; 12.3X48 prior to 12.3X48-D45 on SRX series; 15.1X49 prior to 15.1X49-D75 on SRX series. |
| firewalld.py in firewalld before 0.4.3.3 allows local users to bypass authentication and modify firewall configurations via the (1) addPassthrough, (2) removePassthrough, (3) addEntry, (4) removeEntry, or (5) setEntries D-Bus API method. |
| A vulnerability was discovered in Siemens SIMATIC WinCC Sm@rtClient for Android (All versions before V1.0.2.2). The existing TLS protocol implementation could allow an attacker to read and modify data within a TLS session while performing a Man-in-the-Middle (MitM) attack. |
| In all Android releases from CAF using the Linux kernel, the Hypervisor API could be misused to bypass authentication. |
| A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker in a Man-in-the-Middle position between the SiPass integrated server and SiPass integrated clients to read or modify the network communication. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on the serial port. An attacker can access the serial port on the circuit board of the outdoor unit and log in to the CPE without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| The outdoor unit of Customer Premise Equipment (CPE) product B2338-168 V100R001C00 has a no authentication vulnerability on a certain port. After accessing the network between the indoor and outdoor units of the CPE, an attacker can deliver commands to the specific port of the outdoor unit and execute them without authentication. Successful exploit could allow the attacker to take control over the outdoor unit. |
| A privilege escalation vulnerability in the Secure Shell (SSH) subsystem in the StarOS operating system for Cisco ASR 5000 Series, ASR 5500 Series, ASR 5700 Series devices, and Cisco Virtualized Packet Core could allow an authenticated, remote attacker to gain unrestricted, root shell access. The vulnerability is due to missing input validation of parameters passed during SSH or SFTP login. An attacker could exploit this vulnerability by providing crafted user input to the SSH or SFTP command-line interface (CLI) during SSH or SFTP login. An exploit could allow an authenticated attacker to gain root privileges access on the router. Note: Only traffic directed to the affected system can be used to exploit this vulnerability. This vulnerability can be triggered via both IPv4 and IPv6 traffic. An established TCP connection toward port 22, the SSH default port, is needed to perform the attack. The attacker must have valid credentials to login to the system via SSH or SFTP. The following products have been confirmed to be vulnerable: Cisco ASR 5000/5500/5700 Series devices running StarOS after 17.7.0 and prior to 18.7.4, 19.5, and 20.2.3 with SSH configured are vulnerable. Cisco Virtualized Packet Core - Single Instance (VPC-SI) and Distributed Instance (VPC-DI) devices running StarOS prior to N4.2.7 (19.3.v7) and N4.7 (20.2.v0) with SSH configured are vulnerable. Cisco Bug IDs: CSCva65853. |
| Authentication Bypass vulnerability in the web interface in McAfee Advanced Threat Defense (ATD) 3.10, 3.8, 3.6, 3.4 allows remote unauthenticated users / remote attackers to change or update any configuration settings, or gain administrator functionality via a crafted HTTP request parameter. |
| Incorrect access control in AMAG Symmetry Door Edge Network Controllers (EN-1DBC Boot App 23611 03.60 and STD App 23603 03.60; EN-2DBC Boot App 24451 01.00 and STD App 2461 01.00) enables remote attackers to execute door controller commands (e.g., lock, unlock, add ID card value) by sending unauthenticated requests to the affected devices via Serial over TCP/IP, as demonstrated by a Ud command. |
| The DBD::mysql module through 4.043 for Perl uses the mysql_ssl=1 setting to mean that SSL is optional (even though this setting's documentation has a "your communication with the server will be encrypted" statement), which allows man-in-the-middle attackers to spoof servers via a cleartext-downgrade attack, a related issue to CVE-2015-3152. |
| Revive Adserver before 3.2.3 suffers from Improper Restriction of Excessive Authentication Attempts. The login page of Revive Adserver is vulnerable to password-guessing attacks. An account lockdown feature was considered, but rejected to avoid introducing service disruptions to regular users during such attacks. A random delay has instead been introduced as a countermeasure in case of password failures, along with a system to discourage parallel brute forcing. These systems will effectively allow the valid users to log in to the adserver, even while an attack is in progress. |
| An issue was discovered in Smiths-Medical CADD-Solis Medication Safety Software, Version 1.0; 2.0; 3.0; and 3.1. CADD-Solis Medication Safety Software grants an authenticated user elevated privileges on the SQL database, which would allow an authenticated user to modify drug libraries, add and delete users, and change user permissions. According to Smiths-Medical, physical access to the pump is required to install drug library updates. |
| The admin terminal in Hawt.io does not require authentication, which allows remote attackers to execute arbitrary commands via the k parameter. |
| Nextcloud Server before 9.0.54 and 10.0.1 & ownCloud Server before 9.1.2, 9.0.6, and 8.2.9 suffer from SMB User Authentication Bypass. Nextcloud/ownCloud include an optional and not by default enabled SMB authentication component that allows authenticating users against an SMB server. This backend is implemented in a way that tries to connect to a SMB server and if that succeeded consider the user logged-in. The backend did not properly take into account SMB servers that have any kind of anonymous auth configured. This is the default on SMB servers nowadays and allows an unauthenticated attacker to gain access to an account without valid credentials. Note: The SMB backend is disabled by default and requires manual configuration in the Nextcloud/ownCloud config file. If you have not configured the SMB backend then you're not affected by this vulnerability. |
| Summer Baby Zoom Wifi Monitor & Internet Viewing System allows remote attackers to bypass authentication, related to the MySnapCam web service. |
| With X-Pack installed, Kibana versions 5.0.0 and 5.0.1 were not properly authenticating requests to advanced settings and the short URL service, any authenticated user could make requests to those services regardless of their own permissions. |
| phpMyFAQ before 2.9.8 does not properly mitigate brute-force attacks that try many passwords in attempted logins quickly. |
| A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. |
| Remote enabling and disabling admin interface in Gemalto's HASP SRM, Sentinel HASP and Sentinel LDK products prior to Sentinel LDK RTE version 7.55 leads to new attack vectors. |