Search Results (2011 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2026-42951 2 Danelec, Macgregor 3 Macgregor Voyage Data Recorder (vdr) G4e, Interschalt Vdr G4e, Interschalt Vdr G4e Firmware 2026-06-04 5.4 Medium
An authenticated user can download a backup of the Danelec MacGregor Voyage Data Recorder device which includes account data and password hashes.
CVE-2026-7313 1 Progress 1 Sitefinity 2026-06-04 8.7 High
CWE‑522: Insufficiently Protected Credentials in web services in Progress Sitefinity version from 8.0.5700 to 13.3.7652 allows a remote authenticated attacker to obtain plain-text credentials used connect to Sitefinity Insight service. Successful exploitation requires active integration with Sitefinity Insight, non-default site configuration and valid back-end authorization.
CVE-2026-7312 1 Progress 1 Sitefinity 2026-06-04 10 Critical
CWE‑522: Insufficiently Protected Credentials in web services in Progress Sitefinity version from 14.0.7700 to 14.4.8152, and 15.0.8200 to 15.0.8234, and 15.1.8300 to 15.1.8335, 15.2.8400 to 15.2.8441, 15.3.8500 to 15.3.8531, and 15.4.8600 to 15.4.8630 allows a remote unauthenticated attacker to obtain plain-text credentials used connect to Sitefinity Insight service. Successful exploitation requires active integration with Sitefinity Insight and non-default site configuration.
CVE-2017-7903 1 Rockwellautomation 21 1763-l16awa Series A, 1763-l16awa Series B, 1763-l16bbb Series A and 18 more 2026-06-03 9.8 Critical
A Weak Password Requirements issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 programmable-logic controllers 1763-L16AWA, Series A and B, Version 16.00 and prior versions; 1763-L16BBB, Series A and B, Version 16.00 and prior versions; 1763-L16BWA, Series A and B, Version 16.00 and prior versions; and 1763-L16DWD, Series A and B, Version 16.00 and prior versions and Allen-Bradley MicroLogix 1400 programmable logic controllers 1766-L32AWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWA, Series A and B, Version 16.00 and prior versions; 1766-L32BWAA, Series A and B, Version 16.00 and prior versions; 1766-L32BXB, Series A and B, Version 16.00 and prior versions; 1766-L32BXBA, Series A and B, Version 16.00 and prior versions; and 1766-L32AWAA, Series A and B, Version 16.00 and prior versions. The affected products use a numeric password with a small maximum character size for the password.
CVE-2026-35467 2 Cert/cc, Cmu 2 Cveclient/encrypt-storage.js, Cveclient 2026-06-03 7.5 High
The stored API keys in temporary browser client is not marked as protected allowing for JavScript console or other errors to allow for extraction of the encryption credentials.
CVE-2018-8851 1 Echelon 8 I.lon 100, I.lon 100 Firmware, I.lon 600 and 5 more 2026-06-02 9.8 Critical
Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices store passwords in plaintext, which may allow an attacker with access to the configuration file to log into the SmartServer web user interface.
CVE-2020-15791 1 Siemens 28 Simatic S7-300 Cpu 312, Simatic S7-300 Cpu 312 Firmware, Simatic S7-300 Cpu 314 and 25 more 2026-06-02 6.5 Medium
A vulnerability has been identified in SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions), SIMATIC S7-400 CPU family (incl. SIPLUS variants) (All versions), SIMATIC WinAC RTX (F) 2010 (All versions), SINUMERIK 840D sl (All versions). The authentication protocol between a client and a PLC via port 102/tcp (ISO-TSAP) insufficiently protects the transmitted password. This could allow an attacker that is able to intercept the network traffic to obtain valid PLC credentials.
CVE-2026-41918 1 Siemens 1 Ruggedcom Rst2428p 2026-06-02 5.7 Medium
A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V4.0). The affected applications stores sensitive information in the browser cache when an authenticated user modify specific configurations. This could allow an authenticated attacker to access sensitive data stored in the browser.
CVE-2026-8673 4 Avantra, Linux, Microsoft and 1 more 4 Avantra, Linux Kernel, Windows and 1 more 2026-06-02 5.9 Medium
Unprotected transport of credentials vulnerability in syslink software AG Avantra on Linux, Windows allows Sniffing Attacks. This issue affects Avantra: before 25.3.0.
CVE-2026-49377 1 Jetbrains 1 Teamcity 2026-06-02 4.3 Medium
In JetBrains TeamCity before 2025.11.2 exposure of sensitive data via default agent parameters
CVE-2026-49379 1 Jetbrains 1 Teamcity 2026-06-02 6.5 Medium
In JetBrains TeamCity before 2026.1 credentials could be exposed in thread names
CVE-2026-4387 1 Strongdm 2 Strongdm Desktop Application, Strongdm Desktop Client 2026-06-01 N/A
StrongDM Desktop Application before 23.74.0 (Desktop Client before 53.77.0) on Microsoft Windows stores authentication state, including a JSON Web Token and asymmetric key material, in cleartext in a per-user state file located at C:\Users\<username>\.sdm\state.kv. The file is protected only by default user-level NTFS permissions. Exploitation requires local read access to the affected user's profile directory and additional deployment and execution conditions on the target host. The condition was reported through coordinated disclosure by Hope Walker (SpecterOps).
CVE-2026-0393 1 Codesys 1 Visualization 2026-06-01 6.5 Medium
The affected product may expose credentials remotely between low privileged visualization users during concurrent login operations due to insufficient isolation of authentication data. The vulnerability affects only login operations within an active visualization session.
CVE-2026-32244 1 Discourse 1 Discourse 2026-06-01 5.3 Medium
Discourse is an open-source discussion platform. In versions prior to 2026.1.4, 2026.3.1, 2026.4.1 and 2026.5.0-latest.1, outdated cached AI summaries can leak removed content to anonymous and unprivileged users who cannot regenerate summaries. This issue has been fixed in versions 2026.1.4, 2026.3.1, 2026.4.1 and 2026.5.0-latest.1. To work around this issue, restrict summary generation by tightening the allowed groups on the summarization Personas.
CVE-2024-12604 1 Tapandsign 1 Tap\&sign 2026-06-01 6.5 Medium
Cleartext Storage of Sensitive Information in an Environment Variable, Weak Password Recovery Mechanism for Forgotten Password vulnerability in Tapandsign Technologies Tap&Sign App allows Password Recovery Exploitation, Functionality Misuse. This issue affects Tap&Sign App: before V.1.025.
CVE-2026-48901 1 Joomla 2 Joomla!, Joomla\! 2026-05-28 7.5 High
The InputFilter::getInstance() method omitted a security sensitive parameter from the instance cache key.
CVE-2024-47271 1 Synology 2 Diskstation Manager, Surveillance Station 2026-05-28 4.9 Medium
Insufficiently protected credentials vulnerability in IPSpeaker component in Synology Surveillance Station before 9.2.2-11575 and 9.2.2-9575 allows remote authenticated users with administrator privileges to obtain sensitive information via unspecified vectors.
CVE-2026-9394 1 Besen 1 Bs20 Ev Charging Station 2026-05-27 3.1 Low
A vulnerability was determined in Besen BS20 EV Charging Station up to 20260426. This impacts an unknown function of the component Bluetooth Low Energy Handler. Executing a manipulation can lead to weak password requirements. The attack needs to be done within the local network. This attack is characterized by high complexity. The exploitability is said to be difficult. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."
CVE-2026-2255 1 Hitachi 1 Vantara Pentaho Data Integration And Analytics 2026-05-27 4.3 Medium
Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.2.0.6 and 11.0.0.0, including 9.3.x and 8.3.x, expose Hadoop cluster credentials in plain text through the Cluster Test API. Although the user should not see those explicitly, the defect is mitigated by the fact the user can already leverage those credentials to submit jobs under the same account through the backend API.
CVE-2026-9395 1 Besen 1 Bs20 Ev Charging Station 2026-05-26 3.5 Low
A vulnerability was identified in Besen BS20 EV Charging Station up to 20260426. Affected is an unknown function of the component BLE/UDP. The manipulation leads to insufficiently protected credentials. The attack needs to be initiated within the local network. The original disclosure mentions, that "[t]hese vulnerabilities have been reported to Besen and we have received their acknowlegement that they are reviewing this as of April 2026."